Browse Source

ckdb - stop the confirm reload after it's read all necessary data

master
kanoi 10 years ago
parent
commit
d9ecfc0655
  1. 63
      src/ckdb.c

63
src/ckdb.c

@ -47,7 +47,7 @@
#define DB_VLOCK "1"
#define DB_VERSION "0.7"
#define CKDB_VERSION DB_VERSION"-0.46"
#define CKDB_VERSION DB_VERSION"-0.47"
#define WHERE_FFL " - from %s %s() line %d"
#define WHERE_FFL_HERE __FILE__, __func__, __LINE__
@ -704,11 +704,10 @@ static int64_t confirm_range_finish;
// The workinfoid range we are processing
static int64_t confirm_first_workinfoid;
static int64_t confirm_last_workinfoid;
/* TODO: Stop the reload once we fully complete confirm_last_workinfoid
* and report a message saying so
* This isn't mandatory - but it's simply a waste of processing to continue
* reloading data since it will all be ignored anyway */
static bool confirm_finished;
/* Stop the reload 11min after the 'last' workinfoid+1 appears
* ckpool uses 10min - but add 1min to be sure */
#define WORKINFO_AGE 660
static tv_t confirm_finish;
// DB users,workers,auth load is complete
static bool db_auths_complete = false;
@ -8881,7 +8880,7 @@ static bool reload_from(tv_t *start)
processing++;
count = 0;
while (!matched && !confirm_finished && fgets_unlocked(reload_buf, MAX_READ, fp))
while (!matched && fgets_unlocked(reload_buf, MAX_READ, fp))
matched = reload_line(conn, filename, ++count, reload_buf);
if (ferror(fp)) {
@ -8897,9 +8896,11 @@ static bool reload_from(tv_t *start)
total += count;
fclose(fp);
free(filename);
if (matched || confirm_finished)
if (matched)
break;
start->tv_sec += ROLL_S;
if (confirm_sharesummary && tv_newer(&confirm_finish, start))
break;
filename = rotating_filename(restorefrom, start->tv_sec);
fp = fopen(filename, "re");
if (!fp) {
@ -8957,7 +8958,7 @@ static bool reload_from(tv_t *start)
if (everyone_die)
return true;
if (!matched && !confirm_finished) {
if (!matched) {
ck_wlock(&fpm_lock);
if (first_pool_message) {
LOGERR("%s() reload completed without finding ckpool queue match '%.32s'...",
@ -9343,21 +9344,53 @@ static void confirm_reload()
}
}
workinfo.workinfoid = confirm_first_workinfoid + 1;
workinfo.expirydate.tv_sec = default_expiry.tv_sec;
workinfo.expirydate.tv_usec = default_expiry.tv_usec;
/* These two below find the closest valid workinfo to the ones chosen
* however we still use the original ones chosen to select/ignore data */
/* Find the workinfo before confirm_first_workinfoid+1
* i.e. the one we want or the previous before it */
workinfo.workinfoid = confirm_first_workinfoid + 1;
workinfo.expirydate.tv_sec = date_begin.tv_sec;
workinfo.expirydate.tv_usec = date_begin.tv_usec;
look.data = (void *)(&workinfo);
wi_item = find_before_in_ktree(workinfo_root, &look, cmp_workinfo, ctx);
if (wi_item) {
copy_tv(&start, &(DATA_WORKINFO(wi_item)->createdate));
if (DATA_WORKINFO(wi_item)->workinfoid != confirm_first_workinfoid) {
LOGWARNING("%s() start workinfo not found ... using %"PRId64,
LOGWARNING("%s() start workinfo not found ... using time of %"PRId64,
__func__, DATA_WORKINFO(wi_item)->workinfoid);
}
} else {
start.tv_sec = 0;
LOGWARNING("%s() no start workinfo found ... using 0", __func__);
start.tv_sec = start.tv_usec = 0;
LOGWARNING("%s() no start workinfo found ... using time 0", __func__);
}
/* Find the workinfo after confirm_last_workinfoid-1
* i.e. the one we want or the next after it */
workinfo.workinfoid = confirm_last_workinfoid - 1;
workinfo.expirydate.tv_sec = date_eot.tv_sec;
workinfo.expirydate.tv_usec = date_eot.tv_usec;
look.data = (void *)(&workinfo);
wi_item = find_after_in_ktree(workinfo_root, &look, cmp_workinfo, ctx);
if (wi_item) {
/* Now find the one after the one we found to determine the
* confirm_finish timestamp */
workinfo.workinfoid = DATA_WORKINFO(wi_item)->workinfoid;
workinfo.expirydate.tv_sec = date_eot.tv_sec;
workinfo.expirydate.tv_usec = date_eot.tv_usec;
look.data = (void *)(&workinfo);
wi_item = find_after_in_ktree(workinfo_root, &look, cmp_workinfo, ctx);
if (wi_item) {
copy_tv(&confirm_finish, &(DATA_WORKINFO(wi_item)->createdate));
confirm_finish.tv_sec += WORKINFO_AGE;
} else {
confirm_finish.tv_sec = date_eot.tv_sec;
confirm_finish.tv_usec = date_eot.tv_usec;
}
} else {
confirm_finish.tv_sec = date_eot.tv_sec;
confirm_finish.tv_usec = date_eot.tv_usec;
LOGWARNING("%s() no finish workinfo found ... using EOT", __func__);
}
LOGWARNING("%s() workinfo range: %"PRId64" to %"PRId64" ('%s' to '%s')",